www.incitefire.com.au for technical information 33 Standard Features • Single loop address / Supports two independent zones of conventional detectors • Both zones fully monitored for Short/ Open Circuit • Requires an auxiliary 24Vd.c. supply • DIN rail version available • Both models feature an integral short- circuit isolator Product Overview A Dual Zone Module designed to allow up to 60 conventional detectors (30 per zone) to be interfaced to Hochiki’s Analogue addressable system. Also available as a DIN Rail mountable version. Both models feature an integral short- circuit isolator. CHQ-DZM(SCI) CHQ-DZM(DIN) Standard Features • Loop-powered • Single loop address • Single mains rated relay contact • Relay contact rated at 250Va.c. @ 5 amp (resistive) & 48Vd.c. @ 2 amp (resistive) • Auxiliary monitored input • Screw terminals & flying leads for easy cable termination • DIN rail version available • Both models feature an integral short- circuit isolator Product Overview A Mains Relay Controller providing a single, mains rated relay output for the control of such devices as dampers, extractors or plant and equipment shutdown. The monitored input can be used for local power supply fault monitoring or as a generalpurpose input. Also available as a DIN Rail mountable version. Both models feature an integral short-circuit isolator. CHQ-MRC(SCI) CHQ-MRC(DIN) Standard Features • Loop powered • Single loop address • Two independent inputs for monitoring of volt- free contacts • Each input can be configured to monitor either normally open or normally closed contacts • DIN rail version available • Both models feature an integral short-circuit isolator Product Overview A Dual Input Module designed to interface to a variety of inputs such as door contacts, sprinkler flow/door switches and plant equipment. Also available as a DIN Rail mountable version. Both models feature an integral short-circuit isolator. CHQ-DIM(SCI) CHQ-DIM(DIN) Standard Features • Loop powered • Up to 6 Conventional Detectors • Single loop address • Remote LED output • Fully monitored for short and open circuit faults • DIN rail version available • Both models feature an integral short circuit isolator Product Overview A Single Zone Monitor designed to allow up to 6 conventional detectors to be interfaced to Hochiki’s analogue addressable system. Also available as a DIN Rail mountable version. Both models feature an integral short-circuit isolator. CHQ-SZM(SCI) CHQ-SZM(DIN) Please call Incite Fire Firenet Support team for Firenet spare parts. FIRENET DETECTOR AND DEVICES ( SYNCRO & TAKTIS APPROVED )

RkJQdWJsaXNoZXIy OTk5NjE4