CHQ-PCM-DIN(SCI) Instructions

2-3-0-1156/ISS2/OCT11 Specification Order codes CHQ-PCM(SCI) (module) CHQ-PCM/DIN(SCI) (DIN module) Transmission method Digital communication using ESP Loop Operating voltage 17 - 41 Vdc Quiescent current 300  A Current consumption whilst polling 22 mA  20 % Relay contact rating 30 Vdc max, 1 A (resistive load) Input E.O.L resistor 10 k  ,  5%, 0.25 W Input threshold level ON=470  , Short cct <50  , Open cct >100 K  Isolator Switch current (switch closed) 1 A Leakage current (switch open) 3 mA (max) Weight (g) Dimensions (mm) CHQ Module 332 L157 x W127 x H35 (CHQ Module with lid), 567 H79 (CHQ Module with lid and CHQ-BACKBOX) DIN Module 150 L119 x W108 x H24 (CHQ DIN Module) Colour and enclosure material CHQ Module & CHQ-BACKBOX white ABS, DIN Module green ABS Fire alarm control panel compatibility is required for both variants of this product. See AP0127 for short-circuit isolator specifications. Note:- All EOL and operational resistors are supplied with the unit – DO NOT DISCARD! Installation – "Smart-Fix" Version Set analogue address before installation (see page 1). The fixing surface should be dry and stable.  Hold the back plate up against the fixing surface and mark the position of the four corner fixing holes.  Determine which cut-out sections along the top and bottom edges of the module require removing to accommodate the cables being used.  Remove cut-outs by scoring with a sharp knife before breaking off with pliers or snips.  Mount the back plate using appropriate fixings (not supplied) for the fixing surface.  Terminate and connect field wiring as per the wiring diagrams on pages 2 & 3 (and the terminal block indications on the product label). The transparent lid (CHQ-LID) is supplied with four screws and eight retaining washers.  Push the screws through one of the retaining washers and then through the holes in the lid from front to back, pushing another retaining washer onto the end inside the lid.  Screw the lid onto the back plate; do not over tighten the screws as this could damage the unit. NOTE: A white plastic version of the lid is available (sold separately – CHQ-LID(WHT)). Fig 5 Installation with Back Box For installations requiring glanded cables, a module back box (CHQ-BACKBOX) is available (sold separately). This is mounted on the fixing surface; the CHQ Module is then fitted to the top of the back box and the CHQ-LID is added creating a sealed enclosure. For further details refer to the CHQ-BACKBOX Instructions (2-3-0-800). For CHQ-PCM installations utilising heavy-duty cabling (for example, 1.5mm 2 solid conductor) the use of the SMB-1 Box with the SMB-ADAPTOR plate and CHQ-ADAPTOR is recommended. For further details refer to the SMB-ADAPTOR Instructions (2-3-0-1502). Ensure any glands used (not supplied) conform to IP67, if such ingress protection is required.

RkJQdWJsaXNoZXIy OTk5NjE4