SYNCRO-M2 Brochure
Syncro AS Analogue Addressable Fire Control Panels (1 or 2 Loops) AFP : 2761 Standard Features • ActivFire listed AFP-2761 • Approved to AS7240.2 and AS7240.4 • Available in 1 or 2 loops and networkable up to 64 panels with up to 500 zones per network (the perfect solution for small and large solutions) • 127 devices per loop / Up to 800 sub addresses • LCD display & 16 zone LED indication • Compatible with Hochiki ESP detectors andmodules • Open protocol, non-proprietary software • System enabled with 003 key • Optional OWS available - 20,40,60,120 • Optional fan control available • Capable of driving a high number of loop powered sounders • Base cabinet size 385W x 520H x 110D (mm) • Range of cabinet sizes available Other Features • Standard or deep cabinet options • 16 zonal LED indicators • 5 preconfigured digital inputs • Easily configured using Loop Explorer software • Up to 32 RS485 expansionmodules per panel Product Overview The Syncro AS addressable control panel is designed tomeet the requirements of AS7240.2, AS7240.4 Available in 1 or 2 loops and networkable up to 64 panels with up to 500 zones per network (the perfect solution for small and large projects) The Syncro AS is capable of driving a full loop of 127 sounders @ 85dB Housed in the same installer friendly and attractively styled enclosure as the Sigma CP (conventional) and Sigma XT (extinguishant) range of control panels, the Syncro AS combines compact and practical styling with the programming power and connectivity normally associated withmuch larger systems Additional Features • Comprehensive day/night mode facility • Programmable one touch test mode • Powerful and versatile cause & effect programming • Cause and effect wizard including: • Accomodation Mode • AAF • Non latching detectors • Non fire attributes: Detector options for system control only Key Features 1. Accomodationmode : Accomodationmode is an automatic function that provides a local warning to the occupants and allows a time frame to clear smoke from the detector. This function helps prevent false alarms, fire brigade call outs and their associated costs. 2. Conventional detector connectivity. 3. Seamless wireless connectivity , including detectors, sounders, inputs and outputs 4. LEDmimics, diagramaticmimics and LCDs : Up to 32 devices (Including Syncro View, Ident and Matrix) can be fitted to each panel on the RS485 serial interface. 5. Networking : Up to 64 panels can be addded to a network 6. BuildingManagement Interface: Syncro allows a BMS interface so you can initiate a BMS solution. • Cause and effect action • Disablement configuration • Test mode configuration NSW 02 9644 7144 QLD 07 3252 5366 VIC 03 9544 2211 WA 08 9349 2972
RkJQdWJsaXNoZXIy OTk5NjE4