FBE-70KIT140-AF Brochure

So what makes The Fire Beam different? Two main attributes make The Fire Beam stand out from the crowd. A motorised beam head that continually self-aligns, and a low level controller from which all major functions can be performed. The Motorised Head Up until now, aligning an optical beam could well have been a nightmare, often giving uncertain results that can lead to false alarms. By utilising motors within the beam head, The Fire Beam can make commissioning a safer and more accurate procedure. The unique method of using high quality stepper motors allows us to make micro adjustments of just 1/40 of 1 degree to the beam head. This is automatically controlled by software which finds and continually monitors its position in relation to the reflector. A simple commissioning procedure ensures that you achieve perfect alignment every time and that your beam will keep that alignment. Building movement is the enemy of beam detection, as the smallest movement of a building through heat changes or settlement will move a beam off its target (imagine a couple of degrees of movement in a 100m building). The Fire Beam will continually monitor any movement and re-align itself automatically. How many times have you had to return to a site and re-align beams at high level, and at what expense? The Low Level Controller Low level control means just that. Once you have the head in place and wired in, you can make any changes and adjustments you want from ground level. You can: • commission the beam from ground level • manually move the beam head • view the air quality • view the status of the beam • change sensitivity thresholds • change the time to fire and fault • make the alarm latching or non latching • turn on and off the green flashing light • see fire and fault counts • see how much compensation has been made for dirt build up (you will only have to clean the head and reflector when it needs it) • complete a self test • turn the beam on and off (it will reset itself after 8 hours) • adjust output and receiver settings • and even monitor the temperature at the beam head! Additional Features The Fire Beam has very low power consumption (3.5mA) and can be connected to the fire system detection loop. The Fire Beam IP65 RatingIP65: means no ingress whatsoever making The Fire Beam ideal for environments, such as food processing halls, as it can be hosed down. IP65 also means nasty little creatures can’t set up home inside and jeopardise the effectiveness of the detector. Easy Clean Lenses: The Fire Beam has been designed to be easily cleaned due to its flat surfaces. Unlike other beams, all the moving optics are safely encased inside the waterproof enclosure so you won’t accidentally knock the beam out of alignment. This means The Fire Beam can easily be cleaned from ground level using something like a no-climb pole and suitable attachment. Using The Fire Beam saves time and money Great cost savings can be made over spot and air sampling systems. For example, just one beam can be used instead of 16 spot detectors so cost savings can be considerable. Furthermore, wiring to a single head is more cost effective than fitting yards of air sampling tubing. The advanced technology will greatly reduce commissioning time. It is commonplace to see 25 beams fully commissioned in less than one day. You simply start with one beam and move onto the next, then the next, all from ground level. Spending hours working at height trying to align beams is a thing of the past. Furthermore, self-alignment in normal service means not having to go back and re-align the beam after building movement - again saving time and the expense of lifting equipment, not to mention the disruption this causes. The Fire Beam can also be added to the fire detection loop. The F I REbeam NSW 02 9644 7144 QLD 07 3252 5366 VIC 03 9544 2211 WA 08 9349 2972 xtra

RkJQdWJsaXNoZXIy OTk5NjE4